20 NT008 - TOURÉCHAF TECHNICAL INFORMATION T O U R É C H A F : F A L S E W O R K T O W E R W I T H I N T E G R A L S A F E T Y S Y S T E M An extension can be added using frames and single standards, for example: > Run: > Blocks: - Continuous run: - Run with extensions: Interconnected towers - Run with wind bracing between towers: ou >Towers with extension: On its level and in its plane a single frame can brace up to 4 standards. Beyond 4 standards, a frame or a diagonal brace has to be added. Example: 1 2 3 4 1 2 1 2 3 4 1 2 3 4 5 1 2 3 4 5 1 2 3 4 3 4 >Wind bracing: When the interconnected towers in block are equip- ped with decking at the top,the wind bracing has to be placed at least 1.00 m under the deck in order to avoid possible interference between the diagonal braces and the decks. Temporary ledger for erection. Decking Same principle as a tower with 6 legs. 1.00 Compatibility with scaffolding... Wind bracing and con- necting the towers together is very simple using our ledgers and diagonal braces avoiding “tube and coupler” systems. The wind bracing has to be checked in all vertical planes that comprise a tower. Brace the middle standards. Brace the middle standards.