E S C A L I B M I L L S : S I T E S P I R A L S T A I R T O W E R W I T H S I D E E X I T . 19 > Crane installation of a side access gangway in collective protection: Safety harness use is not required during the assembly phase. WARNING: Anchor the Escalib Mills at the same level as the gangway. WARNING: The lifting operations must be carried out by personnel trained in lifting. > 2 - Install the 2 nd MDS Gangway Bracket intended for the braces. > 1 - Assemble the side access gangway with the Start and an MDS Gangway Bracket. Sling the 2 nd MDS gangway bracket. > 3 - Sling the side access gangway. Install braces at breast height with the M14-100-8.8 bolts. > 4 - Install the side access gangway on the Escalib Mills.Assemble the braces on the 2 nd MDS Gangway Bracket with the M12-100-8.8 bolts. Install the anti- lifting system of the gangway. Unsling. > 5 - If necessary, install the front access gangway on the side access gangway and bolt with the M12-100-8.8 bolts. Open the guardrails for the passage. REQUIREMENTS: > Dismantle in the reverse order of assembly. ESCALIB MILLS NT 010 - ESCALIB MILLS TECHNICAL INFORMATION